alcon sa60at a constantalcon sa60at a constant
In two further optimisations, the formula . Alcon sa60at a constant Cohstant a basic on the remoteamazing developers its password is specify the users. Curamed ASPHERICx HD600YA A=118.4 a0=1.27 a1=0.40 a2=0.10 pACD=5.44 sf=1.68 A=118.8 A=118.9 53 [218]
[134]: data by Dr.Chr.Chassain, Montpellier, France
[278]: data by Jason Jacobs, MD, Denver, CO, USA
[212]: data by Dr.A.Ilkhani, Singen, Germany
[19]: data by K.Gerstmeyer, MD, Minden, Germany
VSY Acriva UD Reviol MF 613 A=118.0 a0=0.65 a1=0.40 a2=0.10 pACD=4.93 sf=1.20 A=118.1 A=118.3 48 [255]
An official website of the United States government. [107]: data by Dr.V.Rasch, Potsdam, Germany
[351]: data by Prof.Rakic, Dr.van Cauwenberge, Liege, Belgium
Spain [155]: data by Prof.Dr.Grabner, Salzburg, Austria
[308]: data by Dr.B.Mathys, Bruxelles, Belgium
Lens Implant SA60D3 Alcon Laboratories, Inc. Fort Worth, TX. HumanOptics Torica-aA(Y) A=118.4 a0=1.18 a1=0.40 a2=0.10 pACD=5.35 sf=1.51 A=118.3 A=118.4 44 [397]
[296]: data by Dr. A. Kerenyi, Budapest, Hungary
[79]: data by Dr.F.Goes, Antwerp, Belgium
[274]: data by Dres.Bascaran and Dr.Oteyza, Oviedo, Spain
All Trademarks referred to are the property of their respective owners. [322]: data by P.Roholt MD, Canton OH, USA
The biconvex optic and supporting haptics consist of a high refractive index soft acrylic material. Gen. Innov. [341]: data by Fredrick Lang MD, Cecanot, Dominican Republic
Biotech Vision Bioacryl 60125 discont. ATTENTION: Refer to the Directions for Use labeling for a complete list of indications, warnings and precautions.REFERENCES: https://professional.myalcon.com/cataract-surgery/intraocular-lens/acrysof-iq-monofocal-iol/. Treatment of negative dysphotopsia with supplementary implantation of a sulcus-fixated intraocular lens. Visiontech Medical Optics Liteflex A A=118.2 a0=1.21 a1=0.40 a2=0.10 pACD=5.36 sf=1.57 A=118.6 A=118.7 48 [276]
[374]: data by Dr. J. Joergensen, Dr. R.C. J Cataract Refract Surg. VSY Acriva UD 613 A=118.0 a0=0.95 a1=0.40 a2=0.10 pACD=5.19 sf=1.43 A=118.4 A=118.6 49 [254]
[237]: data by Dr.Matteo Piovella, Monza, Italy
[273]: data by Dr. Karin Bz, Hamburg, Germany
Uruguay Staar AQ 2003V A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.73 sf=1.96 A=119.2 A=119.6 65 [54]
[90]: data by Dr.R.Wiedemann, Leipzig, Germany
[101]: data by Peter C.Campanella, MD, Sinking Spring, PA, USA
Description. [385]: data by Dr. GO Byung Woo, Seoul, South Korea
[293]: data by Tomasz Trzos, Grlitz, Germany
Purpose: To compare vision-related quality of life and higher-order aberrations (HOAs) with an aspherical intraocular lens (IOL) (AcrySof IQ SN60WF) and a conventional spherical IOL (AcrySof SA60AT) (both Alcon) after phacoemulsification. Alcon AcrySof MA60BM (Japan) A=118.9 a0=1.98 a1=0.40 a2=0.10 pACD=6.10 sf=2.32 A=119.8 A=120.5 99 [41]
Polytech Polylens H10(Y10) (+) A=118.1 a0=1.10 a1=0.40 a2=0.10 pACD=5.27 sf=1.51 A=118.5 A=118.7 55 [201]
[335]: data by Dr. Ralf Gerl, Ahaus, Germany
[220]: data by Dr.Georg Leuschner, Garbsen, Germany
A-constants provided as a guideline only. [380]: data by Dr. LEE Junhun, Daegu, South Korea
[350]: data by Dres. The lens has a biconvex optic with supporting haptics. [10]: data by R.Walter-Fincke, MD, and W.Bachmann, MD, Aschaffenburg, Germany
[58]: data by R.Kaufer, MD, Argentina
[392]: data by Dr. M. Gamringer-Kroher, Weiden, Deutschland
[281]: data by Medicontur Ltd, Hungary
U.Weimantel MD(Karlsruhe, Germany),
Oculentis LU-313T A=118.0 a0=0.97 a1=0.40 a2=0.10 pACD=5.18 sf=1.37 A=118.2 A=118.2 162 [394]
All rights reserved. [376]: data by Mr. Mark Cahill, Dublin, Ireland
Nidek Nex-Acri AA A=119.5 a0=1.56 a1=0.40 a2=0.10 pACD=5.73 sf=1.95 A=119.2 A=119.7 167 [18]
AMO Tecnis ZM900 A=119.0 a0=1.60 a1=0.40 a2=0.10 pACD=5.89 sf=2.21 A=119.8 A=120.5 118 [71],[72],[77],[79]
[250]: data by Veronica M. Ferguson, London, UK
[1]: HAIGIS W, LEGE B, MILLER N, SCHNEIDER B: Comparison of immersion ultrasound
[84]: data by Dr.W.Bachmann,Aschaffenburg, Germany
Europe / Middle East / Africa [166]: data by Prof.Dr.F.Kruse, Erlangen, Germany
[309]: data by Dr.F.DeWilde, Sint Martens Latem, Belgium
[325]: data by Dr. Julio Fernandez Mendy, Buenos Aires, Argentina
[120]: data by Dr.L.Tschernjakov, Berlin, Germany
Domilens Nidek NS-60YG Aktis SP y A=118.4 a0=1.61 a1=0.40 a2=0.10 pACD=5.81 sf=2.03 A=119.3 A=119.7 127 [264],[226],[313]
J.Strobel MD(Jena, Germany),
[106]: data by Dr.E.Becker, Oranienburg, Germany
AMO SI55 A=118.0 a0=1.10 a1=0.40 a2=0.10 pACD=5.28 sf=1.56 A=118.7 A=119.1 77 [2],[18]
Our services and technology are covered by the partnering members with the end goal of making healthcare more affordable and transparent. [170]: data by Dr.A.Parasta, Mnchen, Germany
Zemaitiene R, Speckauskas M, Glebauskiene B, Jasinskas V. Kugelberg M, Wejde G, Jayaram H, Zetterstrm C. J Cataract Refract Surg. AMO Tecnis ZMB00 (Hongkong) A=118.8 a0=1.93 a1=0.40 a2=0.10 pACD=6.14 sf=2.35 A=119.7 A=119.7 51 [280]
[205]: data by Prof.Dr.J.Alio, Alicante, Spain
Bausch&Lomb BL27 A=117.8 a0=1.16 a1=0.40 a2=0.10 pACD=5.31 sf=1.55 A=118.6 A=119.0 96 [30]
Oculentis L-303 A=118.0 a0= 0.962 a1= -0.074 a2=0.161 pACD=5.13 sf=1.36 A=118.3 A=118.4 250 [119],[120],[117],[170],[120],[118],[160]
The Alcon MA60AL 3-piece acrylic optic and haptic intraocular lens (IOL) was introduced in January 1995. [41]: data by C.Suto, MD, Tokyo, Japan
[340]: data by Dr. Hanemoto, Mito, Japan
ZEISS CT ASPHINA 409M (Acri.Smart 46LC) A=117.7 a0=0.322 a1=0.162 a2=0.158 pACD=5.12 sf=1.36 A=118.3 A=118.5 662 [73],[212],[154],[233],[266],[326],[376]
[284]: data by Prof.Dr.G.Alessio, Bari,Italy
Range . Technoko TA625 A=118.0 a0=1.17 a1=0.40 a2=0.10 pACD=5.32 sf=1.59 A=118.7 A=119.1 40 [54]
Alcon ReSTOR SV25T0 A=119.1 a0=1.66 a1=0.40 a2=0.10 pACD=5.82 sf=2.07 A=119.5 A=119.8 70 [147],[367]
Zarracom Focusforce Basic F260 A=118.4 a0=1.55 a1=0.40 a2=0.10 pACD=5.68 sf=1.93 A=119.2 A=119.9 49 [347]
[263]: data by Dr. J.-M. Bosq, Nantes, France
Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Augsburg,Herzberg, Germany
Krmer, Domeier und Pache, Lbeck, Germany
[53]: data by Dr.P.Gruber, Forch, Switzerland
[35]: data by F.Kremer, MD, Troisdorf, Germany
In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparisonof a new material IOL to other monofocal IOLs. [348]: data by Dr.Budo, Belgium; Dr.Krantz-Kret, The Netherlands
Oculentis L-403 A=118.0 a0= 1.02 a1=0.40 a2=0.10 pACD=5.16 sf=1.41 A=118.4 A=118.7 14 [106]
[387]: data by Dr. BAE Gye Jong, Incheon, South Korea
ZEISS CT ASPHINA 509M (India) A=118.3 a0=0.61 a1=0.40 a2=0.10 pACD=4.78 sf=0.99 A=117.6 A=117.6 198 [342]
[316]: data by Prof.Dr.E.Fabian, Rosenheim, Germany
[233]: data by Dr.R.Schmid, Dillingen, Germany
[69]: data by Dr.H.Strobl, Rosenheim, Germany
[264]: data by Dr. C.Niederdellmann, Friedberg, Germany
Please note:
[270]: data by Dr.A.Rosa Almeida, Ipatinga, Brazil
If you continue to use this site we will assume that you are happy with it. [15]: data by J.Chvojkova, MD, Prague, Czech Republic
HumanOptics Aspira-aA(Y) (+) A=118.4 a0=0.429 a1=0.236 a2=0.151 pACD=5.31 sf=1.56 A=118.6 A=119.0 295 [396],[70]
[248]: data by Kazuo Ichikawa MD, Nagoya, Japan
[391]: data by Dr. C. Ameye, Essen, Germany
[326]: data by Dr. Paul O'Brian, Dublin, Ireland
Das KK, Werner L, Collins S, Hong X. [12]: data by E.Frieling, MD,Mnchen, Germany
Domilens Siflex4 discontinued A=118.4 a0=1.18 a1=0.40 a2=0.10 pACD=5.43 sf=1.71 A=118.9 A=119.5 83 [2],[18]